Cath Lab Simulator

This simulator needs a computer with a keyboard.

The C-arm, wires, catheters, balloons and stents are steered with the keys, on a large screen. It does not work on a phone. Please open it again on a laptop or desktop computer.

About the simulator

Educational model - not for clinical decisions. © Copyright kardiologi.se

Cath Lab Simulatorv11 Coronary angiography and PCI trainer © Copyright kardiologi.se
Contrast
0 mL
X-ray time
0:00
Air kerma
0 mGy
Cine runs
0

How to use the simulator

Diagnostic angiography

  1. First step, always: insert the 0.035" angio guidewire and advance it into the ascending aorta (hold W, press ↓).
  2. Choose a catheter (JL4 for the left, JR4 for the right coronary) and advance it over the wire into the aortic root (hold C, press ↓). Remove the wire, then steer the tip into the ostium: hold C, ↓ advances, ↑ pulls back, ← / → turn counter-clockwise / clockwise. A JL4 drops into the left ostium when advanced; a JR4 is advanced and turned clockwise. The buttons Engage left / right do it for you.
  3. Set a projection: presets, sliders, arrow keys or drag the image.
  4. Hold Space for fluoroscopy. Hold Enter to inject contrast and record a cine run - about 2-3 seconds fills the vessel. Hold Space and Enter together for a quick contrast check under fluoroscopy (not recorded).
  5. Ventriculography: choose the pigtail catheter, bring it over the wire onto the aortic valve and push it on into the left ventricle (hold C, press ↓). Remove the wire, set RAO 30 and inject with cine.
  6. Repeat in several views. To change the catheter: disengage, advance the 0.035" wire again, choose the other catheter, remove the wire.
  7. Use Mark lesion, click the stenosis, name the segment and grade it. Then submit the report.

PCI

  1. 0.035" wire into the ascending aorta, then a 6F guiding catheter over it (hold C, press ↓). Remove the wire, engage and give heparin.
  2. Insert the 0.014" coronary wire. Hold W: the arrow keys now steer the wire - ↓ push, ↑ pull back, ←/→ turn the tip to choose branches. Park the tip distally.
  3. Measure the vessel (QCA, Length) and choose a balloon or stent. Load it and advance it - hold B (balloon) or S (stent) and press ↓ (↑ pulls back) - until the markers bracket the lesion - check with a contrast injection.
  4. Hold I to inflate, watch the pressure, press D to deflate.
  5. Post-dilate if needed, record the final result in two views and end the procedure.

Keyboard

↑ ↓LAO / RAO
← →Cranial / caudal
Space (hold)Fluoroscopy (F also works)
Enter (hold)Contrast injection + cine
Space + Enter (hold)Contrast under fluoroscopy (low dose, not recorded)
P + ↓ / ↑Pacing lead advance / pull back (hold P)
C + ↓ / ↑Catheter advance / pull back (hold C)
C + ← / →Turn the catheter in the aortic root: counter-clockwise / clockwise (hold C)
W + ↓ / ↑Wire push / pull back (hold W)
W + ← / →Turn the wire tip (hold W)
B + ↓ / ↑Balloon advance / pull back (hold B)
S + ↓ / ↑Stent advance / pull back (hold S)
E / QStill work: device advance / pull back
I (hold)Inflate
DDeflate
ShiftFine, slow movement

Good to know

  • The image only updates while X-ray is on. Otherwise you see the last image hold, as in a real lab.
  • The reference monitor stores every cine run as a numbered loop. Step between runs with the arrows below it, click the image to pause, and use the square in the corner for full screen (arrow keys and Space work there too).
  • Length measurements are 2D: a foreshortened view under-measures the lesion.
  • The anatomy guide and steering hints are training aids. Switch them off to test yourself.

Disclaimer

No catheter in place

No guidewire in place

Load a balloon

Temporary pacemaker

Lead via the right internal jugular vein into the right ventricle. Advance it under fluoroscopy: hold P, press ↓ (↑ pulls back).

Unfractionated heparin i.v.

Choose the bolus in international units (IU).

Atropine i.v.

Choose the dose. Raises the heart rate; in bradycardia also the blood pressure.

Nitroglycerin intracoronary

Choose the dose. Blood pressure falls for a few minutes, more after 250 µg.

Scores are teaching feedback, not a certification of clinical competence.